McDATA OPENconnectors Command Line Interace Uživatelský manuál Strana 257

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 328
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 256
A
Error Messages
A-17
Message Error 112: No Threshold Definition Given
Description The threshold value for the alert was not configured before the user
attempted to activate the alert.
Action Set the threshold value, then try to activate the alert.
Message Error 115: Invalid Switch Speed
Description The request cannot be completed because the switch is not capable of
operating at the configured speed.
Action Consult the installation/service manual to determine the speed
capabilities of your product.
Message Error 116: Switch Not Capable of 2 Gb/sec
Description The request cannot be completed because the switch is not capable of
operating at 2 Gb/sec.
Action Consult the installation/service manual to determine the speed
capabilities of your product.
Message Error 117: Port Speeds Cannot be Set at Higher Data Rate than
Switch Speed
Description This request cannot be completed because the requested port speed is
faster than the currently-configured switch speed.
Action The switch speed should first be configured to accommodate changes
in the configured port speed. The ports cannot operate at a faster rate
than the switch, itself. Update the switch speed and re-submit the
request. For more information, see config.switch.speed on page 2-78
and config.port.show on page 2-27.